Panasonic Home Business > Industrial Devices > Automation Controls Top > Service & Support > Frequently Asked Questions

What is the cause and method of rectifying Err 50.1 external scale communication data fault protection?

ID:
40402
Issued:
Apr 3rd, 2017
Updated:
Apr 27th, 2017

What is the cause and method of rectifying Err 50.1 external scale communication data fault protection?

ANSWER
■ Cause
The data from the external scale has generated a communication fault. Primarily data fault caused by EMI. The connection cable with the external scale is in place but communication data is faulty.
■ Action
Secure the power voltage of the external scale DC 5 V ± 5% (4.75 - 5.25 V). Use caution if the connection cable with the external scale is long.
If the motor wire and external scale cable are bundled together, separate them.
Connect the shield to FG and refer to the connection diagram for the external scale.