Panasonic Home Business > Industrial Devices > Automation Controls Top > Service & Support > Frequently Asked Questions

What is the cause and method of rectifying Err 44.0: Single revolution counter fault protection, and Err 45.0: multi-revolution counter fault protection encoder?

ID:
40416
Issued:
Apr 3rd, 2017
Updated:
Apr 18th, 2017

What is the cause and method of rectifying Err 44.0: Single revolution counter fault protection, and Err 45.0: multi-revolution counter fault protection encoder?

ANSWER
■ Cause
 Err44.0: Generated while the encoder power supply (5 V) is ON, and when single revolution data causes malfunction or shifts due to failure.
 Err45.0: Generated when a fault occurs in the counting signal of multi-revolution data while the encoder power supply (5 V) is ON.
    (This does not operate when the encoder power is off.)
• If the encoder is an incremental system,
 Err45.0 does not occur.

■ Action
• If stress (thrust, radial load) is applied to the motor shaft, the encoder rotation disc gap will wobble, possibly causing a malfunction. If the generation frequency is high, encoder failure is possible and replacement of the motor is required.
• If the generation frequency is low, malfunction due to EMI is possible. After implementing EMI prevention measures, such as installing a ferrite core in the encoder cable, evaluate their effectiveness.