What is the main difference between the DQ relay scheduled to be discontinued, and the recommended replacement DZ-S relay?
- ID:
- 40933
- Issued:
- Sep 10th, 2018
- Updated:
- Sep 18th, 2018
What is the main difference between the DQ relay scheduled to be discontinued, and the recommended replacement DZ-S relay?
- ANSWER
-
• The major specification difference is as follows.
(1) The dimensions and terminal layout are different. Also, the DZ-S relay cannot be placed on a circuit board.
(2) The contact rating is different.
DQ relay à 30A 250 V AC
DZ-S relay à 90 A 250 V AC
(3) The type of coil rated voltage is different.
DQ-M relay à 4.5 V DC, 6 V DC, 9 V DC, 12 V DC, 24 V DC
DZ-S relay à 5 V DC, 12 V DC, 24 V DC
For other detailed specifications, please refer to the attached data sheet.